MKS GEN L V2.1

2 Orders
#MZ493
In stock
450,000

Mô tả

MKS GEN L V2.1

GEN-L

How to Adjust Driver Current.
Caution!
Please mind the power polarity and  drivers direction.
Please don’t put the drivers or motors on/off while power on.
Please disconnect all motors when adjust driver current.
A4988(1amp)
I= vref /1.6,default Vref 1.6V and 0.5A,Max1.0A.
A4988(2amp)
I= vref /0.8,default Vref 0.8V and 1.0A,Max2.0A.
DRV8825
I= vref *2, default 0.65A and 1.3A,Max 2.5A.
LV8729
I= vref /0.5, default 0.4A and 0.8A,Max 1.5A.
microstep

 

 

 

Tags


Warning: sizeof(): Parameter must be an array or an object that implements Countable in /home/u463436857/domains/linhkien283.com/public_html/wp-content/themes/aloshop/woocommerce/content-single-product.php on line 100
Top
Call Now Button